Conditions of use
• Applications : Drinking water metering for high flow rate (irrigation, industry, water supply system).
• Suitable for sediment-laden waters (sand, stones and other impurities).
• The upstream pipe must be straight on 10xDN and the downstream pipe must be straight on 5xDN (U10D5).
• Horizontal mounting (MID R40), vertical mounting or inclined mounting.
• Pressure : PN 16 bar.
• Temperature : 0°C / +50°C.
Technical features
• Tangential turbine.
• Removable mechanism (easy dismantling and maintenance).
• 360° rotating dry dial with protective cover.
• Magnetic transmission.
• Reading by rolls (m3).
• Sealing, protection against external magnetic fields.
• Cast iron body.
• GN16 flanges according to EN 1092-2.
• MID Accuracy class : Horizontal mounting R40. Other mountings no-certified MID.
• Low pressure loss (0.1 bar max. - 0.25 bar max. for DN50).